+34 972 58 20 40inoxmim@inoxmim.com

FacebookPinterestCompanyYouTubeLinkedIn

Bomba de engranajes externos FL-ENC de InoxMIM sobre bancadaBomba de engranajes FL-ENC montada sobre carro con cuadro de maniobra

Gear pumps · FL50ENC to FL140ENC series

FL-ENC external gear pump

Fixed-flow external gear pump, robust and able to work at high pressures, for pumping viscous products in the chemical and food industries: oils, fats, molasses, starch, cellulose, creams or chocolates. Four sizes, from 500 to 15,000 l/h and up to 14 bar.

  • 15 m³/hMaximum flow rate (FL140ENC)
  • 14 barMaximum pressure, entire series
  • Ductile ironPump body
  • Quenched and tempered F-127Carbon steel gears
  • DIN 2576Standard connections
  • ReversiblePumps in both directions
  • Ductile iron body
  • DIN 2576 connections
  • Reversible
  • Low noise level

Prefer to speak to a technician? Call 972 58 20 40 or write to inoxmim@inoxmim.com

What is the FL-ENC external gear pump for?

The FL-ENC is a positive displacement pump: the pump shaft drives one gear (the driving gear), which turns the other (the idler gear), and the fluid flows between the teeth of the two. It delivers a fixed flow rate, works at high pressures and combines high reliability with very effective sealing.

It is well suited to dosing and transferring viscous products and to products handled at temperature: the optional heating jacket, at the front and rear, prevents the product from solidifying. The body is made of ductile iron, the gears of quenched and tempered F-127 carbon steel and the shafts of F-5 steel with a stainless steel coating. The series ranges from the FL50ENC, up to 4,000 l/h, to the FL140ENC, up to 15,000 l/h, all at 14 bar.

FL-ENC gear pump on a trolley with control panel

This is the right pump if…

  • It pumps oils, fats, molasses, starch, cellulose, creams or chocolates.
  • You need high pressures, of up to 14 bar.
  • You are looking for fixed flow rates from 500 to 15,000 l/h.
  • The product has to be kept hot so that it does not solidify.

Choose other equipment if…

Applications by industry

Products the catalogue lists for the FL-ENC in the chemical and food industries:

Oils and fats

Transfer and dosing of oils and fats, with a heating jacket if they tend to solidify.

Molasses and sugars

Pumping of molasses and other dense products at pressures of up to 14 bar.

Chocolates and creams

Chocolates and creams handled at a controlled temperature.

Starch and cellulose

Viscous products from the chemical industry, such as starch and cellulose.

Features and benefits

High pressures

Up to 14 bar on all sizes in the series.

Fixed flow rate

Positive displacement pump: the flow rate is stable and suitable for dosing and transferring viscous products.

Reversible

It pumps in both directions.

Hot operation

High performance and the ability to work at high temperatures, with optional heating jacket.

Robust construction

Ductile iron body, quenched and tempered F-127 gears and iron baseplate: long service life in extreme conditions.

Quiet and compact

Low noise level and a compact, highly reliable design.

Models in the series

Choose the size by flow rate. The standard connections are DIN 2576; the table shows the sizes with special connections.

ModelFlow rateMax. pressureFree passage ØDIN 11851Clamp / GASWeight (bare shaft)
FL50ENC500–4,000 l/h14 bar29 mmDN25–DN321" / 1"–1¼"48.5 kg
FL70ENC1,000–7,000 l/h14 bar50 mmDN40–DN501½"–2" / 1½"–2"54 kg
FL100ENC3,000–10,000 l/h14 bar67 mmDN65–DN802"–2½" / 2"–2½"63 kg
FL140ENC5,000–15,000 l/h14 bar80 mmDN80–DN1003"–4" / 3"73.5 kg

Data from the FLUIDMIM catalogue. The weight is for the bare-shaft pump, without motor. The full dimensions are in the technical data sheet.

Technical data

Materials

Pump body

Ductile iron

Gears

Quenched and tempered F-127 carbon steel

Shafts

F-5 carbon steel with AISI 304L or 316L coating

Baseplate

Iron

Hydraulics

Principle

External gears, positive displacement

Flow rate

500 to 15,000 l/h depending on the model

Maximum pressure

14 bar

Direction of rotation

Reversible

Mounting

Standard

On baseplate

Shaft

Keyways and keys to DIN 6885/1

Connections

Standard

DIN 2576

Special connections

DIN 11851, GAS, Clamp, RJT, etc.

Options and customisation

Heating jacket

Heated by electric heating elements, steam or hot water to prevent the product from solidifying.

Pressure control

Pressure control device using a pressure switch.

Temperature control

Temperature control device using probes.

Trolley

Iron or stainless steel trolley to move the pump around the plant.

CE control panel

With start/stop, reversing switch, 10 m of cable and plug.

Special connections

DIN 11851, GAS, Clamp or RJT, among others, instead of the standard DIN 2576.

Other positive displacement pumps

FL-ENM monobloc gear pump

FL-ENM monobloc gear pumpMonobloc in AISI 316 for dosing, up to 2,000 l/h.

FL-PRL lobe pump

FL-PRL lobe pumpFor viscous liquids: up to 70 m³/h and 100,000 cP.

FL-EF progressive cavity pump

FL-EF progressive cavity pumpProgressive cavity with floating stator, wetted parts in AISI 316.

View all gear pump models →

Frequently asked questions about the FL-ENC external gear pump

What flow rate and pressure does the FL-ENC deliver?

Depending on the size, from 500 to 15,000 l/h: the FL50ENC reaches 4,000 l/h, the FL70ENC 7,000 l/h, the FL100ENC 10,000 l/h and the FL140ENC 15,000 l/h. All of them work at up to 14 bar.

Can it be used in the food industry?

Yes, the catalogue intends it for the chemical and food industries, for oils, fats, molasses, creams or chocolates. Bear in mind that the body is made of ductile iron; if the process requires wetted parts in stainless steel, the option is the FL-ENM, in AISI 316, or the FL-PRL lobe pump.

What is the heating jacket for?

To pump products that have to be handled hot without them solidifying in the pump. It is optional, located at the front and rear, and heated by electric heating elements, steam or hot water.

What is the difference from the FL-ENM monobloc gear pump?

The FL-ENC is larger and works at higher pressure: up to 15,000 l/h and 14 bar, with a ductile iron body on a baseplate. The FL-ENM is monobloc, with wetted parts in AISI 316, and is designed for dosing up to 2,000 l/h at 2 bar.

How is it protected against overpressure?

With the optional pressure switch. In a positive displacement pump the pressure rises if the discharge is closed, so a device that stops the motor before the working pressure is exceeded is advisable.

What maintenance does it need?

Basically, check the sealing and the wear on the gears and shafts as often as the use requires. It must not run dry: the product itself lubricates the gears.

Request a quote for the FL-ENC external gear pump

Equipment: FL-ENC external gear pump

Tell us what product you are pumping, the flow rate, the working pressure, the viscosity and the temperature, and whether you need a heating jacket. With these data we will indicate the right size and options.